Vertical Bitumen Storage

Highly efficient and economical vertical bitumen storage tanks

The Parker High Efficiency Vertical Bitumen tanks have been designed and developed to be used on sites where space is at a premium.


Energy costs are high and trends would suggest a continued rise in the longer term. Within the quarrying industry bitumen storage is a significant contributor to energy usage but due to its secondary nature in the day to day operation of a coating plant it may not always be given the attention it deserves. Therefore when purchasing a new bitumen tank thermal efficiency should be an important consideration in the decision making process.

A new Parker High Efficiency Vertical Bitumen Storage Tank can provide significant energy savings and reduce an operation’s carbon footprint. There is an ever increasing focus on the environmental and safety issues surrounding bitumen spillage. Parker ensures its tanks conform to industry best practice guidelines regarding safe handling of bitumen, including safe working capacity, available ullage, accurate contents gauges and high level alarms all of which greatly reduce the risk of spills occurring.


  • Conforms to RBA best practice relating to safety
  • Range of heating options available
  • Capacities from 30,000 - 200,000 liters
  • Accurate continuous level indication
  • 300mm thick high efficiency insulation
  • Temperature Indication monitoring
  • Independent ultimate high level alarm
  • Optional top mounted tank agitator
  • Traffic light fill system
  • Easy to operate & requires minimal maintenance

Features


Construction

Fabricated cylindrical tank. Submerged ARC weld inside & out. Compliant to current RBA recommendations. Carbon steel BSEN standard.

Termal Insulation

300mm high density thermal wool insulation. Staggered joints for greater heat retention. 75mm more Insulation as standard.

Efficient Foil Blanket

Greater thermal resistance. Improved energy saving. Weather-proof material ensures added protection against the elements.

Heating Technology

Removable ceramic electric heating elements. Increased heat transfer. Easy to replace and maintain. Totally enclosed heater bank.

Tank Fittings

Guide wave radar level indicator. High level/low level audio & visual alarms. Optional agitators for PMB storage. Optional access ladders.

Pump & Pipe Work

Bitumen pump & valves. Bespoke pipe work installations. Fill point traffic light indicators. Optional telemetry systems.

Minimal Heat Loss

Thermographic image showing minimal heat loss.

Specifications


  Units High Efficiency Vertical Bitumen Storage Tanks
Safe Working Capacity* Tonnes 30 40 50 60 70 80 90 100
Dimensions
Overall Height A m 6.52 8.22 9.71 11.19 12.90 14.61 13.25 14.62
inches 256 3/4” 323 3/4” 382 1/4” 440 1/2” 508” 575 1/4” 521 3/4” 575 1/2”
Overall Diameter B m 3.61 3.61 3.61 3.61 3.61 3.61 3.97 3.97
inches 142 1/4” 142 1/4” 142 1/4” 142 1/4” 142 1/4” 142 1/4” 156 1/4” 156 1/4”
Heating System
Total Load kW 45 45 45 45 45 60 60 60
Switching Stages Unit 3 3 3 3 3 3 3 3
Elements Unit 9 9 9 9 9 12 12 12
Siting Details1
Base Diameter m 3.00 3.00 3.00 3.00 3.00 3.00 3.35 3.35
inches 118 1/4” 118 1/4” 118 1/4” 118 1/4” 118 1/4” 118 1/4” 132” 132”
Other Information
Lagging Depth mm 300 300 300 300 300 300 300 300
inches 12” 12” 12” 12” 12” 12” 12” 12”
Complies With RBA Guidelines -
tank

Find Out More




Brochures

Please
login
or
register
to download our brochures
High Efficiency Vertical Bitumen Storage
1359
1358
1357

Horizontal Bitumen Storage

Renowned for their durability and long service life, Parker horizontal tanks are available in a range of sizes from 30 - 100 tonnes.

The tanks can be supplied with three types of heating system all fully thermostatically controlled and incorporating all necessary controls and safety systems:

  1. Electrically heated tanks are fitted with high efficiency ceramic bridge full length immersion heaters and are ideal for use where low cost off-peak electricity supplies are readily available.

  2. Thermal oil heated tanks incorporate internal heat transfer coils heated by a Parker external heat exchanger and are ideal where electric supplies are limited or where gas or light oil are the fuel of choice.

  3. Direct oil fired tanks are heated using oil fired burners and can be used in any scenario.


  • High degree of fabrication integrity
  • Capacities of 30 - 100 tonnes
  • Range of heating options available
  • Thermostatically controlled temperature
  • Accurate continuous level indication
  • High density insulation and robust external finish
  • Independent ultimate high level alarm
  • Easy to operate & requires minimal maintenance
  • Ideal for sites with height restrictions
  • Rapid on site set up times/ pre wired and tested.

Features


Construction

  • Fabricated cylindrical tank
  • Submerged ARC weld inside & out
  • Compliant to current RBA recommendations
  • Carbon steel BSEN standard

Insulation / Finish

  • Increased thermal retention
  • Improved energy saving
  • Weather-proof Galv/SS finish
  • 100mm high density insulation
  • Staggered joints reduce heat loss

Pump & Pipe Work

  • Complete pipe work design and installation - a complete package.
  • Fill point traffic light indicators.
  • External Or Submerged bitumen pump options available.

Electrically Heated Option

Electrically heated including the latest safety control systems. The heating nest consists of banks of individually removable ceramic heating elements that operate on a graduated switching system.

Low maintenance operation & economical use of low tariff off-peak electricity supply.

Thermal Oil Heated Option

Utilising direct oil fired heating with fully automatic, thermostatically controlled burner systems and full safety systems.

Suitable for remote locations with limited or no mains electricity supply.

Direct Oil Fired Option

Heated using indirect thermal oil coils, the heat source being provided the Parker CHY oil heat exchanger range allowing great flexibility in the design of a complete installation.

Maximum temperature setting to reduce the risk of over heating the product

Suitable for remote locations with limited or no mains electricity supply

Options


  • Electrically heated tanks - Fitted with high efficiency ceramic bridge full length immersion heaters. Ideal for use where low cost off-peak electricity supplies are readily available
  • Thermal oil heated tanks - Incorporate internal heat transfer coils heated by a Parker external heat exchanger and are ideal where electric supplies are limited or where gas or light oil are the fuel of choice.
  • Direct oil fired tanks - Heated using oil fired burners and can be used in any scenario

Find Out More




Brochures

Please
login
or
register
to download our brochures
Horizontal Bitumen Storage
1381
1380
1383

Mobile Bitumen Storage

The Parker Fast Mover Bitumen Storage Tank is the ideal solution for mobile plants such as those used for asphalt, recycling and foamed bitumen applications.

Designed to the highest standards for safe and efficient operation the tank is fully self-contained, and comes mounted on a semi chassis for rapid deployment.

Fully insulated for increased thermal retention it can be offered with three options for heating electric, direct oil fired and thermal oil all of which are thermostatically controlled.

The Fast Mover can be supplied complete with on-board pump and low-level ring main and is designed to either be operated singly or units can be connected together to provide storage for a number of bitumen grades.


  • Capacities from 30,000 - 60,000 litres
  • Range of heating options available
  • Full thermostatic control
  • Independent ultimate high level alarm
  • Accurate continuous level indication
  • High density insulation and robust external finish
  • Rapid on site set-up times
  • Several units can be easily linked to create a tank farm
  • Option for onboard pump/s
  • Easy to operate and requires minimal maintenance

illustration

Features


Construction

  • Fabricated cylindrical tank
  • Submerged ARC weld inside & out
  • Compliant to current RBA recommendations
  • Carbon steel BSEN standard

Insulation / Finish

  • Increased thermal retention
  • Improved energy saving
  • Weather-proof Galv/SS finish
  • 100mm high density insulation
  • Staggered joints reduce heat loss

Bitumen Heating Options

  • Electric 415V ceramic immersion heating elements
  • Cartem CHY fully automatic indirect hot oil heating
  • Automatic direct oil fired burner heating

Pump & Pipework

  • On board rotary gear bitumen pump
  • Integrated primary/secondary tank pipe work
  • Optional flexible interconnecting steel braided transfer hose

Valves & Pneumatics

  • High quality butterfly and gate valves
  • Mechanical/radar level monitoring
  • Pneumatically operated 3-way bitumen ring main valve

Controls

  • Easy and simple to operate
  • Thermostatically controlled heating
  • Digital temperature controller
  • 24/7 time clock with back up power
  • Contents level audio and visual alarms

Find Out More




Brochures

Please
login
or
register
to download our brochures
Mobile Bitumen Storage
 
1408
 

ISO Bitumen Transportation Containers

The Parker ISO 20 Bitumen Container is designed to provide the ideal multi-modal solution for the transportation of bitumen world-wide.

Constructed as a standard 20 foot ISO tank container with Lloyd's approval it is suitable for transportation by sea, road and rail and allows a number of containers to be set up to provide a temporary or semi-permanent tank farm on site.

We offer a full installation package to suit individual needs including light fuel oil burners, pumps and pipe work.

  • High degree of fabrication integrity
  • Payload capacity of 29,000 litres
  • Lloyd's approval for shipping as a tank container
  • Direct oil fired heating system
  • Twin heating tubes to permit rapid elevation of product temperature
  • Rigid foam insulation and robust external finish
  • Optional stainless steel flame tube liners to prevent localised hot spots
  • Optional fully automatic pressure jet burners
  • Easy to operate & require minimal maintenance
  • Rapid on site set up times
iso with key

Key

  1. ISO Container - Outer Tank
  2. Inner Tank - 29,000L Capacity
  3. ‘U’ Shaped Flame tubes
  4. Quick Fit Fully Automatic Burners
  5. Internal Surge Protection Plates
  6. Quick Fit Exhaust Flues
  7. Drain/Discharge Valves Points
  8. Fill Point Connection

Features


Outer Tank

  • Standard 20 foot ISO container
  • ISO 1496 part 3 – type 75 container
  • Lloyds approved
  • One 200mm inlet spigot on the roof to allow quick filling

Inner Tank

  • Rectangular section fabricated from 4mm plate
  • Baffle plates fitted to prevent liquid surge
  • 75mm of rigid foam insulation fitted
  • Two “U” shaped flame tubes to permit rapid heating
  • Two flanged burner mountings
  • Two flanged exhaust stack mountings

Heating Method

  • Stainless steel liners to prevent localised hotspots
  • 240V fully automatic oil burners
  • ‘Easifit’ electrical connections with ‘DIN’ plug and socket connections
  • Skid mounted transportable fuel tank with flexible connections to burners

Control Panel

  • Lockable IP55 cabinet with weather canopy
  • Plug and socket connections for incoming power and burner supply
  • Individual burners controlled from the panel
  • Thermostatic temperature control of product

Transfer Discharge Pump

  • Rotary gear type skid mounted pump
  • Electrically heated
  • Capacity of 21,000 litres per hour
  • Driven by 7.5 kW direct coupled electric motor

Flexible Hose Assemblies

  • Braided steel bitumen hoses
  • Canvas covered
  • For connection from container to pump and to other equipment

Find Out More


1369
1368
1370

Mobile Emulsion Storage

Self contained bulk storage tanks, designed to modern operational safety standards, fully insulated and mounted on a semi-trailer chassis they can be positioned close to the work site to maximise output.

With thermostatically controlled heating to maintain temperature and an onboard pumping system for loading, offloading and circulating material, they provide the complete answer for increased productivity on spraying contracts.


  • Capacities from 30,000 - 60,000 litres
  • Electrically heated or direct oil fired options
  • High level alarm with audio and visual displays
  • Accurate contents monitoring system
  • High density insulation
  • Onboard pump for loading, discharge & circulation
  • Hydraulically erected man way platform handrails
  • On board generator for areas without electrical supply
  • Thermostatic temperature control
  • Easy to operate & requires minimal maintenance
illustration

Features


Construction

  • Fabricated cylindrical tank
  • Submerged ARC weld inside & out
  • Compliant to current RBA recommendations
  • Carbon steel S235JR standard

Integral Pump & Valves

  • Reliable and efficient hydraulically driven rotary gear type pump enclosed in a hotbox
  • Robust ball valve & gate valve types

Insulation / Finish

  • Greater thermal resistance
  • Weather-proof Stainless Steel Finish
  • 100mm high density Insulation
  • Staggered joints reduce heat loss

Heating Method

  • Two fully automatic pressure jet oil burners electrically driven from diesel hydraulic power pack at 240V
  • Or external electrical supply to electric pump & ceramic immersion heaters

Hydraulic Handrails

  • Simple to operate, minimal effort
  • Safely erected from ground level
  • UK compliance
  • Vehicles brakes are automatically disabled once handrails are erect

Controls

  • Digital temperature controller
  • 24/7 Time clock with backup power
  • Content level audio and visual alarms
  • Thermostatically controlled

Find Out More